Classification of air quality for manufacture of sterile products
Clean room classes |
A |
B |
C |
D |
|||
Comparable clean room class according to... |
|||||||
US Fed. Std.209 |
100 |
100 |
10,000 |
100,000 |
|||
VDI 2083 |
3 |
3 |
5 |
6 |
|||
Type of air flow |
Laminar flow in the working area |
Non-laminar flow |
Non-laminar flow |
Non-laminar flow |
|||
Air change |
1/h |
360-540 |
>20 |
>20 |
>20 |
||
Average air velocity |
m/s |
||||||
vertically |
0.3 |
- |
- |
- |
|||
horizontally |
0.45 |
- |
- |
- |
|||
Maximum permitted number of viable microorganisms |
1/m3 |
<1* |
max. 5* |
max. 100 |
max. 500 |
||
Maximum permitted number of particles |
1/m3 |
||||||
≧0.5 mm |
3,500 |
3,500 |
350,000 |
3,500,000 |
|||
≧5 mm |
none |
none |
2,000 |
20,000 |
|||
※The marked low values can be reliably determined only by a great number of air samples.